Installation model: AMC300LS
Rated operating power: 300 kW
Rated voltage: 415V
Rated current: 542 A
Technical characteristics of the gas generator unit model AMC300LS
The installation operates on low-pressure liquefied petroleum gas (pressure 367 kPa). Gas enters the installation after the buffer tank (if necessary, the tank is purchased by the customer independently). Once the generator is brought to stable operation, one 415 V power line is supplied. The line is connected to the ATS automatic load transfer switch (purchased by the customer if necessary), then to the customer's distribution panel. Cables outside the generator set frame are supplied by the customer.
Main parameters of the gas generator plant
Unit model: AMC300LS Rated operating power: 300 kW Rated voltage: 415 V Rated current: 542 A Rated frequency: 50 Hz Starting method: 24 V electric start Voltage regulation system: AVR automatic voltage regulator Overall dimensions of the unit (length × width × height), mm: 3000 × 1100 × 1650 (reference data, final dimensions for the actual product) Installation weight, kg: 5000 (reference data, final weight for the actual product) Installation design: monoblock design. The base is made of high-strength steel. The cooling fan and battery charger are equipped with protective covers.
Operating conditions
Altitude above sea level: no more than 1000 m Ambient temperature: from -15 °C to +40 °C Relative humidity: no more than 90% Manufacturing standards: GB/T2820, GB/T12786-1991
1. Cost-effective
The optimized air-fuel ratio reduces exhaust gas temperatures, extends engine life and reduces maintenance costs.
Precise control of the gas combustion process increases fuel efficiency by 5–10% compared to analogues.
The control system is certified by the China Maritime Classification Society CCS, the equipment has stable operation and high reliability, and the operating costs for the entire service life are minimal.
2. Fast response to load
Supersonic gas injectors ensure precise fuel dosage and instant engine response to load changes; the unit can withstand sudden abrupt connections and disconnections of heavy loads. There are a large number of successful operational examples at large oil and gas fields (drilling complexes, hydraulic fracturing installations), as well as at industrial enterprises with variable load conditions.
3. Environmental emissions indicators
Exhaust emissions comply with Euro 5 standards or T3 standard for off-road vehicles and higher.
The concentration of nitrogen oxides NOx is less than 200 parts per million (ppm).
4. Additional benefits
Short delivery time: the minimum delivery time for equipment is 1 week.
Integrated plug-and-play design: complete commissioning and power supply possible in one working day, installation is easy to transport and transfer between sites.
A complete multi-level equipment protection system; more than 20 years of project implementation without accidents.
Software update service throughout the entire service life, the ability to remotely monitor the status of the station from anywhere.